Echothiophate

Echothiophate (Phospholine) is an irreversible acetylcholinesterase inhibitor.[1]

Echothiophate
Clinical data
Trade namesPhospholine
Routes of
administration
Topical (eye drops)
ATC code
Identifiers
CAS Number
PubChem CID
DrugBank
ChemSpider
UNII
KEGG
ChEBI
ChEMBL
Chemical and physical data
FormulaC9H23INO3PS
Molar mass383.23 g·mol−1
3D model (JSmol)
 NY (what is this?)  (verify)

Uses

It is used as an ocular antihypertensive in the treatment of chronic glaucoma and, in some cases, accommodative esotropia. It is available under several trade names such as Phospholine Iodide (Wyeth-Ayerst).

Echothiophate binds irreversibly to cholinesterase. Because of the very slow rate at which echothiophate is hydrolyzed by cholinesterase, its effects can last a week or more. Adverse effects include muscle spasm and other systemic effects.

Mechanism of action

It covalently binds by its phosphate group to serine group at the active site of the cholinesterase. Once bound, the enzyme is permanently inactive and the cell has to make new enzymes.

Shortage

Wyeth Pharmaceuticals stopped manufacturing echothiophate iodide in the US in 2003. After contacting the American Academy of Ophthalmology (AAO), Wyeth rescinded their decision and, according to AAO public relations representative Michelle Stephens, the AAO and Wyeth were in talks for about a year about manufacturing it.[2]

In the meantime, a worldwide shortage of the drug has occurred.

Chemistry

Echothiophate is made by reacting diethylchlorophosphoric acid with 2-dimethylaminoethylmercaptan, giving S-(2-dimethylaminoethyl)-O,O-diethylthiophosphate, which is alkylated by methyl iodide, forming echothiophate.[3]

gollark: Yet another failed summon...
gollark: (not actual quote)
gollark: "Reading takes away from the amount of time I could spend complaining about new things!"
gollark: That reminds me, I should hatch that mageia.
gollark: I'll probably only try and get about 5 (garland, wrapping-wing, new release, winter magi, wait that's four).

References

  1. Gabelt BT, Hennes EA, Seeman JL, Tian B, Kaufman PL (August 2004). "H-7 effect on outflow facility after trabecular obstruction following long-term echothiophate treatment in monkeys". Invest. Ophthalmol. Vis. Sci. 45 (8): 2732–6. doi:10.1167/iovs.04-0083. PMID 15277498.
  2. "Eurotimes article: "Echothiophate iodide shortage leaves US specialists struggling to find alternative for acute cases"". Archived from the original on 2006-06-19. Retrieved 2006-08-13.
  3. H.M. Fitch, U.S. Patent 2,911,430 (1959)
This article is issued from Wikipedia. The text is licensed under Creative Commons - Attribution - Sharealike. Additional terms may apply for the media files.