Paris Métro train fire

The disastrous Paris Métro train fire occurred on the evening of 10 August 1903, on what was then Line 2 Nord of the system and is now Paris Métro Line 2. There were 84 deaths, most at Couronnes station, so it is also known as the Couronnes Disaster.

Removal of victims' bodies after the fire
L'Actualité number 187, 16 August 1903

Fire

The line, less than a year old, was mostly underground, but included an elevated section four stations long from Boulevard Barbès to Rue d'Allemagne inclusive (today Barbès – Rochechouart and Jaurès respectively; see List of stations of the Paris Métro). It was worked by a mixture of 4-car (single) and 8-car (double) trains, of the M1 stock, which turned on loop tracks at each end of the line so that the same car remained in front. On a single train, only the front car had motors; a double train had one motor car at each end, but the power for both cars was routed through the front car, as multiple-unit train control had not yet come into use.

On 10 August 1903, the first sign of trouble was at 6:53 p.m., when double train 43 completed the climb to Boulevard Barbès station with heavy smoke pouring from one of the motors on its front car, car M202. The train's passengers were evacuated onto the platform and its shoes were lifted from the third rail to cut off the power, whereupon the burning subsided. But with the station full of annoyed passengers, the staff now focused their attention on restoring service. That meant moving the train, and there was no siding before the line descended back into the tunnel.

The fatal decision was made to lower the shoes and move it under its own power, when in fact the motor had not simply overheated, but had a short circuit. Train 43 left the station at 7:05 p.m. amid a cloud of black smoke, but before it had passed two stations, the fire on car M202 had reignited with greater intensity. Unaware of the severity of the situation, the driver kept the train moving until it was back in the tunnel, and only then stopped for help at the first station (Combat, now Colonel Fabien). Again the shoes were lifted and the burning stopped — and again power was reapplied, and the fire restarted. This time the wooden paddles used to lift the shoes were consumed.

The driver was still focused on moving the train off the line, but clearly it could not be driven from the front, and there was no way to electrically disconnect the motor cars and drive it from the rear. So he now asked for a push. By this time the passengers waiting at Barbès had boarded the next train (single train 52), which had then advanced as far as Rue d'Allemagne and was waiting for the signal to continue. It was now unloaded in turn onto the platform there and driven to Combat, where it coupled onto the rear of train 43. At 7:32 p.m. the triple train began moving slowly forward, powered by a single motor car and with the short circuit on the front car M202 still live and feeding the fire.

Meanwhile, the following train (train 48, another single train), advanced to Rue d'Allemagne and the passengers from trains 43 and 52 crowded onto its four cars. The combined train 43-52 next passed Belleville station. At this station there was a siding, but the failed train could not be put into it; it would have to continue to the end of the line at Nation, 8 stations later. As the train limped past the next station, Couronnes, its stationmaster was justifiably alarmed at the obvious signs of fire. By the time train 48 arrived there with its triple load of passengers, eddying smoke was visible in the tunnel ahead. Rather than pulling forward to the station exit as usual, the driver stopped his short train halfway along the platform to confer with the stationmaster.

With the danger finally understood, the decision was made to evacuate to the street — but by now the passengers, some of them having already been ejected from two trains, were becoming uncooperative. A fare refund was demanded, a lively altercation ensued, and then suddenly it was too late. Train 43-52 had barely reached the next station, Ménilmontant, when the fire grew out of control and the crew fled for their lives. Power was cut at the nearest substation, but since the line was not divided into electrically isolated sections, the shorted motor was still receiving power from other substations.

At about 8 p.m. the fire destroyed the one circuit supplying the station lighting. Couronnes station was plunged into darkness just as a dense, choking cloud of smoke emerged from the tunnel leading to Ménilmontant. In less than a minute, the station had become a death trap. Disoriented by the smoke and far from the exit, many people wandered the wrong way until they succumbed to asphyxia.

In all, 84 people were killed: 75 at Couronnes, seven at Ménilmontant, and two who tried to escape through the tunnel. The wooden-bodied train was completely destroyed.

Hazards corrected

Just eight days after the disaster, the Métro system was ordered to undertake a series of corrective measures:

  • Immediately
    • Responsible managers must be assigned to each section of each line, ready to take charge in case of any incident
    • Drivers must be told to isolate short-circuited motors from the power supply
    • Exits must have lighted signs
    • Temporary firefighting stations must be provided until hydrants are installed
    • Stations must have unobstructed exit routes
  • Within 15 days
    • Electrical components must be fully insulated
    • Flammable materials must be eliminated, particularly from drivers' cabs
    • Fire hydrants must be installed
    • A second, protected lighting power supply must be installed (this was placed under the track)
  • By 1 November 1903
    • Each line must be divided into electrically isolated sections
    • Station exits must be widened

The double trains were quickly reduced from eight cars to seven, with the two motor cars now placed together at the front. But within a few years, in perhaps the disaster's most enduring legacy, multiple-unit trains were adopted. By using much lower currents in their control circuits, these greatly decreased the risk of fire in the case of a traction power failure.

gollark: What?
gollark: PotatOS also does that.
gollark: I have the same thing but better and without time.
gollark: We could even duel for the elections!
gollark: I agree with djm. We need a keansian duelling arena.

See also

References

  • Jean Tricoire, Un Siècle de Métro en 14 Lignes: De Bienvenüe à Météor, 2nd edition 2000 (Éditions La Vie du Rail), ISBN 2-902808-87-9.
  • Jean Robert, Notre Métro, 1st edition 1967 (Musée des Transports Urbains, AMTUIR).
  • Brian Hardy, Paris Metro Handbook, 1st edition, 1988 (Capital Transport Publishing), ISBN 1-85414-104-X.

Note: Of these sources, Tricoire gives the most detailed account of the fire and has been accepted as correct on details where the sources conflict.

This article is issued from Wikipedia. The text is licensed under Creative Commons - Attribution - Sharealike. Additional terms may apply for the media files.