International Commission on Radiation Units and Measurements

The International Commission on Radiation Units and Measurements (ICRU) is a standardization body set up in 1925 by the International Congress of Radiology, originally as the X-Ray Unit Committee until 1950. Its objective "is to develop concepts, definitions and recommendations for the use of quantities and their units for ionizing radiation and its interaction with matter, in particular with respect to the biological effects induced by radiation".[1]

The ICRU is a sister organisation to the International Commission on Radiological Protection (ICRP). In general terms the ICRU defines the units, and the ICRP recommends how they are used for radiation protection.

Development

Using early Crookes tube X-Ray apparatus in 1896. One man is viewing his hand with a fluoroscope to optimise tube emissions, the other has his head close to the tube. No precautions are being taken.
Monument to the X-ray and Radium Martyrs of All Nations erected 1936 at St. Georg hospital in Hamburg, commemorating 359 early radiology workers.

During the first two decades of its existence, its formal meetings were held during the International Congress of Radiology, but from 1950 onwards, when its mandate was extended, it has met annually. Until 1953, the president of the ICRU was a national of the country that was hosting the ICR, but in that year it was decided to elect a permanent commission - the first permanent chairman being Lauriston S. Taylor who had been a member of the commission since 1928 and secretary since 1934. Taylor served until 1969 and on his retirement was accorded the position of honorary chairman which we held until his death in 2004, aged 102.[2]

In the late 1950s the ICRU was invited by the CGPM to join other scientific bodies to work with the International Committee for Weights and Measures (CIPM) in the development of a system of units that could be used consistently over many disciplines. This body, initially known as the "Commission for the System of Units" (renamed in 1964 as the "Consultative Committee for Units") was responsible overseeing the development of the International System of Units (SI).[3]

In the late 1950s the ICRU started publishing reports on an irregular basis - on average two to three a year. In 2001 the publication cycle was regularised and reports are now published bi-annually under the banner "Journal of the ICRU".[4][5]

Current operation

The commission has a maximum of fifteen members who serve for four years and who, since 1950, have been nominated by the incumbent commissioners. Members are selected for their scientific ability and is widely regarded as the foremost panel of experts in radiation medicine and in the other fields of ICRU endeavor. The commission is funded by the sale of reports, by grants from the European Commission, the US National Cancer Institute and the International Atomic Energy Agency and indirectly by organisations and companies who provide meeting venues. Commissioners, many of whom have full-time university or research centre appointments, have their expenses reimbursed, but otherwise they receive no remuneration from the ICRU.

Radiation quantities

External dose quantities used in radiation protection and dosimetry based on ICRU 57, jointly developed with the ICRP

The commission has been responsible for defining and introducing many of the following units of measure. The number of different units for various quantities is indicative of changes of thinking in world metrology, especially the movement from cgs to SI units.[6]

The following table shows radiation quantities in SI and non-SI units.

Ionizing radiation related quantities
QuantityUnitSymbolDerivationYearSI equivalence
Activity (A) becquerel Bq s−1 1974 SI unit
curie Ci 3.7 × 1010 s−1 1953 3.7×1010 Bq
rutherford Rd 106 s−1 1946 1,000,000 Bq
Exposure (X) coulomb per kilogram C/kg C⋅kg−1 of air 1974 SI unit
röntgen R esu / 0.001293 g of air 1928 2.58 × 10−4 C/kg
Absorbed dose (D) gray Gy J⋅kg−1 1974 SI unit
erg per gram erg/g erg⋅g−1 1950 1.0 × 10−4 Gy
rad rad 100 erg⋅g−1 1953 0.010 Gy
Equivalent dose (H) sievert Sv J⋅kg−1 × WR 1977 SI unit
röntgen equivalent man rem 100 erg⋅g−1 x WR 1971 0.010 Sv

Although the United States Nuclear Regulatory Commission permits the use of the units curie, rad, and rem alongside SI units,[7] the European Union European units of measurement directives required that their use for "public health ... purposes" be phased out by 31 December 1985.[8]

Administration

The Commission's secretariat is in Stockholm and its legal status is that of British charity (Not-for-profit organisation).

gollark: Alternatively, only have a screen, accelerometer and one button.
gollark: Anything but reed switches is BLOAT!!!!! ! !!!!!!! Just wave magnets at your calculator for that sci-fi aesthetic.
gollark: Or, well, accusing random things of being bloat.
gollark: Isn't talking about bloat, in a sense, bloat?
gollark: Switches are bloat. Just plug wires in to do what you want.

See also

Videos

References

  1. Wambersie, A; Menzel, HG (26–30 August 2002). The ICRU: General Objectives and Achievements with regard to Occupational Radiation Protection (PDF). Occupational Radiation Protection: Protecting workers against exposure to ionising radiation. Geneva. pp. 99–110. Retrieved 31 May 2012.
  2. "Emeritus and founder member L S Taylor dies". International Commission on Radiological Protection. 1 December 2004. Retrieved 18 June 2012.
  3. "CCU: Consultative Committee for Units". International Bureau of Weights and Measures (BIPM). Retrieved 18 May 2012.
  4. "Reports". International Commission on Radiation Units and Measurements. Retrieved 3 June 2012.
  5. "Journal of the ICRU". Oxford University Press. 2012. Retrieved 3 June 2012.
  6. "International Commission on Radiation Units and Measurements" (PDF). International Commission on Radiation Units and Measurements. 14 March 2012. Retrieved 1 June 2012.
  7. 10 CFR 20.1004. US Nuclear Regulatory Commission. 2009.
  8. The Council of the European Communities (1979-12-21). "Council Directive 80/181/EEC of 20 December 1979 on the approximation of the laws of the Member States relating to Unit of measurement and on the repeal of Directive 71/354/EEC". Retrieved 19 May 2012.
This article is issued from Wikipedia. The text is licensed under Creative Commons - Attribution - Sharealike. Additional terms may apply for the media files.