Nitrazine
Nitrazine or phenaphthazine is a pH indicator dye often used in medicine. More sensitive than litmus, nitrazine indicates pH in the range of 4.5 to 7.5. Nitrazine is usually used as the disodium salt.
Names | |
---|---|
IUPAC name
(3E)-3-[(2,4-Dinitrophenyl)hydrazono]-4-oxonaphthalene-2,7-disulfonic acid | |
Other names
Nitrazine yellow; Phenaphthazine | |
Identifiers | |
3D model (JSmol) |
|
ChemSpider | |
PubChem CID |
|
| |
| |
Properties | |
C16H10N4O11S2 | |
Molar mass | 498.40 g/mol |
Except where otherwise noted, data are given for materials in their standard state (at 25 °C [77 °F], 100 kPa). | |
Infobox references | |
Use
Nitrazine (pH indicator) | ||
below pH 4.5 | above pH 7.5 | |
4.5 | ⇌ | 7.5 |
- This test is done to ascertain the nature of fluid in the vagina during pregnancy especially when premature rupture of membranes (PROM) is suspect. This test involves putting a drop of fluid obtained from the vagina onto paper strips containing nitrazine dye. The strips change color depending on the pH of the fluid. The strips will turn blue if the pH is greater than 6.0. A blue strip means it's more likely the membranes have ruptured.
This test, however, can produce false positives. If blood gets in the sample or if there is an infection present, the pH of the vaginal fluid may be higher than normal. Semen also has a higher pH, so recent vaginal intercourse can produce a false reading.
- To perform a fecal pH test for diagnosing intestinal infections or other digestive problems[1]
- In civil engineering, to determine the carbonatation spread in concrete structures and therefore assess the state of the rebar's passivation film.
gollark: You seem to be suggesting that a lack of headphone jacks is fine because I can just carry another device for no non-headphone-jack reason.
gollark: I don't want to carry two devices when my phone has an entirely usable audio player app (and can even do video, and store 128GB of stuff, and that sort of thing), and actually has a headphone jack.
gollark: ... but my phone can play audio fine?
gollark: Especially since the alternative seems to just be proprietary headphone things which use up the one port on most phones.
gollark: I think being annoyed about the dropping of a standard and useful I/O feature for dubious reasons is fair.
References
- "Point-of-Care Testing, Fecal pH Measurement". Archived from the original on 2007-07-03.
This article is issued from Wikipedia. The text is licensed under Creative Commons - Attribution - Sharealike. Additional terms may apply for the media files.