Actinism

Actinism (/ˈæktɪnɪzəm/) is the property of solar radiation that leads to the production of photochemical and photobiological effects.[1] Actinism is derived from the Greek ακτίς, ακτῖνος (a ray or beam). The word actinism is found, for example, in the terminology of imaging technology (esp. photography), medicine (concerning sunburn), and chemistry (concerning containers that protect from photo-degradation), and the concept of actinism is applied, for example, in chemical photography and X-ray imaging.

Actinic (/ækˈtɪnɪk/) chemicals include silver salts used in photography and other light sensitive chemicals.

In chemistry

In chemical terms, actinism is the property of radiation that lets it be absorbed by a molecule and cause a photochemical reaction as a result. Albert Einstein was the first to correctly theorize that each photon would be able to cause only one molecular reaction. This distinction separates photochemical reactions from exothermic reduction reactions triggered by radiation.

For general purposes, photochemistry is the commonly used vernacular rather than actinic or actino-chemistry, which are again more commonly seen used for photography or imaging.

In medicine

In medicine, actinic effects are generally described in terms of the dermis or outer layers of the body, such as eyes (see: Actinic conjunctivitis) and upper tissues that the sun would normally affect, rather than deeper tissues that higher-energy shorter-wavelength radiation such as x-ray and gamma might affect. Actinic is also used to describe medical conditions that are triggered by exposure to light, especially UV light (see actinic keratosis).

The term actinic rays is used to refer to this phenomenon.[2]

In biology

In biology, "actinic light" denotes light from solar or other sources that can cause photochemical reactions such as photosynthesis in a species.

Photography

Actinic light was first commonly used in early photography to distinguish light that would expose the monochrome films from light that would not. A non-actinic safe-light (e.g., red or amber) could be used in a darkroom without risk of exposing (fogging) light-sensitive films, plates or papers.

Early "non colour-sensitive" (NCS) films, plates and papers were only sensitive to the high-energy end of the visible spectrum from green to UV (shorter-wavelength light). This would render a print of the red areas as a very dark tone because the red light was not actinic. Typically, light from xenon flash lamps is highly actinic, as is daylight as both contain significant green-to-UV light.

In the first half of the 20th century, developments in film technology produced films sensitive to red and yellow light, known as orthochromatic and panchromatic, and extended that through to near infra-red light. These gave a truer reproduction of human perception of lightness across the color spectrum. In photography, therefore, actinic light must now be referenced to the photographic material in question.

In manufacturing

Actinic inspection of masks in computer chip manufacture refers to inspecting the mask with the same wavelength of light that the lithography system will use.

In aquaculture

Actinic lights are also common in the reef aquarium industry. They are used to promote coral and invertebrate growth.[3][4] They are also used to accentuate the fluorescence of fluorescent fish.

Actinic lighting is also used to limit algae growth in the aquarium.[5] Since algae (like many other plants), flourish in shallower warm water, algae cannot effectively photosynthesize from blue and violet light, thus actinic light minimizes its photosynthetic benefit.

Actinic lighting is also a great alternative to black lights as it provides a "night environment" for the fish, while still allowing enough light for coral and other marine life to grow. Aesthetically, they make fluorescent coral "pop" to the eye, but in some cases also to promote the growth of deeper-water coral adapted to photosynthesis in regions of the ocean dominated by blue light.

Artificial lighting

"Actinic" lights are a high-color-temperature blue light. They are also used in electric fly killers to attract flies.

gollark: Apiary packet handling can be based on RFC 6214 with extensions and more puns.
gollark: oh bees oh no
gollark: You like x86, and you like syscalls, so evidently you should do it?
gollark: <@!356107472269869058> write esolang where the only operation is x86 syscalls
gollark: Hmm, thus demote coltrans establish anarchy?

See also

  • Spectral sensitivity is commonly used to describe the actinic responsivity of photographic materials.

References

  1. Appendix 3. "Units for photochemical and photobiological quantities", pp.173-174 of The International System of Units (SI), BIPM, 2006
  2. "actinic rays" at Dorland's Medical Dictionary
  3. Aquarium Lighting information
  4. The Correct Lighting for Your Aquarium
  5. "Archived copy". Archived from the original on 2015-01-12. Retrieved 2014-12-02.CS1 maint: archived copy as title (link) What is Actinic Lighting
This article is issued from Wikipedia. The text is licensed under Creative Commons - Attribution - Sharealike. Additional terms may apply for the media files.