Introduction

Use this guide to replace a broken, cracked, or defective screen on your Apple Watch Series 8.

It is possible to replace the screen of the Apple Watch Series 8 without removing or disconnecting the battery first. However, this can lead to a malfunction of the NFC antenna under certain circumstances. If you feel comfortable with your repair, skip the battery removal steps in this guide. Otherwise, follow this guide in it‘s original order.

Replacing the display can cause issues with Apple Pay. If possible, to reduce the likelihood of problems, delete all your Apple Pay account info before the replacement, and then re-enter it with the new display installed.

This guide shows the procedure on the 45 mm cellular/LTE version of the watch, but the GPS-only version is similar.

You’ll need replacement adhesive to reattach the battery and the screen when reassembling the device.

  1. 2JKGaQ2llkWWNSFh
    2JKGaQ2llkWWNSFh
    SHt6Nm14f6nLriap
  2. XLlxiv5vC2JpN6Th
    XLlxiv5vC2JpN6Th
    VeSHVQSw5IFaRfFZ
    yMiLR1blIH1DFX2x
    • Because the gap between the screen and watch body is so thin, an iFlex is needed to separate the two.

    • Protect your fingers by keeping them completely clear of the iFlex edge. If in doubt, protect your free hand with a heavy glove, such as a leather shop glove or gardening glove.

    • Be careful not to apply too much pressure, as this might cause the iFlex to slip and cut you, or damage the watch.

    • Wear eye protection. If the opening procedure is performed incorrectly or with too much pressure, the glass could crack, sending small glass shards flying.

    • Attach or remove the watch band as needed to provide more control as you make repairs.

  3. L1w3XHynNUeWPDjC
    • Prepare an iOpener and apply it to the screen for three minutes to loosen the adhesive underneath.

    • A hair dryer, heat gun, or hot plate may also be used, but be careful not to overheat the watch—the display and internal battery are both susceptible to heat damage.

    • You may need to reheat the iOpener and repeat this procedure several times until the display adhesive softens.

  4. wUaeTCCNIGrsmFrT
    wUaeTCCNIGrsmFrT
    1QWQDLQi4i1V1Z4s
    6FxmTFrEGKUOc2Px
    • Take your time and work carefully to avoid scratching the watch body with your iFlex.

    • Insert the iFlex into the thin gap between the display and frame at the edge adjacent to the digital crown.

    • Tilt the iFlex down to pry the display open slightly and create a gap between the screen and the watch body.

    • The Apple Watch Series 8 display is equipped with a plastic bezel on its rear side. If you want to reuse your display, avoid using too much pressure with the iFlex or you may separate the bezel from the screen.

  5. SVcVEsLGoFNAgYuG
    SVcVEsLGoFNAgYuG
    CdLKcq2JWmdjqH1a
    • Insert the tip of an opening pick into the gap you just created.

    • Slide the opening pick along the short edge of the watch to slice the adhesive.

  6. TuXXlrcmC4AXcEth
    TuXXlrcmC4AXcEth
    K3kdnNve3CiFQGNK
    • Slide the opening pick around the corner and along the long edge opposite to the watch crown to slice the adhesive.

  7. MJAtuLQZJinN3nY1
    MJAtuLQZJinN3nY1
    ejWGeCltJnwVKRDa
    • Slide the opening pick around the corner and along the next short edge to slice the adhesive.

  8. yxbStDd4aQfhO3SM
    yxbStDd4aQfhO3SM
    QKXLYS6plsIdxBfG
    • When slicing the adhesive on the edge with the watch crown, only insert the opening pick 2–3 mm to prevent damaging the display cables.

    • Slide the opening pick around the corner and toward the watch crown to slice the remaining adhesive.

    • Don't try to fully remove the display yet, as it‘s still connected to the watch assembly.

  9. DgDjp2CXQQFWKX13
    DgDjp2CXQQFWKX13
    MONFt4BEwEaCl5Gw
    jRuJfLLpZPqqi4yt
    • Be careful not to strain the display cables when you open the display.

    • Lift the display and carefully pull it towards the watch crown.

    • Swing the display open to an upright position.

    • To reseal your watch follow this general Apple Watch resealing guide.

  10. awqiM5bBFRkJxWFa
    • Prepare an iOpener and apply it to the rear glass for two minutes to loosen the adhesive underneath the battery.

    • A hair dryer, heat gun, or hot plate may also be used, but be careful not to overheat the watch—the display and internal battery are both susceptible to heat damage.

  11. GCNxHZf5VJYNWYd4
    GCNxHZf5VJYNWYd4
    xXjnJZVkbVYYdAXN
    awwPYA6QSFICCgwh
    • Take care not to puncture or bend the battery with your tool—a punctured or bent battery may leak dangerous chemicals or cause a fire.

    • Insert an opening pick into the gap between the watch body and the long edge of the battery.

    • Use constant, steady pressure to slowly pry up the battery.

    • Don't try to remove the battery all the way yet, as it‘s still connected to the motherboard.

  12. FfhqKwTlsCkZ5yiX
    FfhqKwTlsCkZ5yiX
    lmIJE66GDmyRGatI
    • The battery flex cable is long enough to allow you to place the battery outside the watch housing, but avoid straining or sharply folding the cable when you lift the battery out of its recess.

    • Carefully lift the battery out of its recess and place it next to the watch body.

  13. yACMsNHTpXCACWgF
    • Use a Tri-Point Y000 screwdriver to remove the 1.1 mm-long screw securing the battery connector bracket.

  14. UZWUSJUxBHQRYST1
    UZWUSJUxBHQRYST1
    i44pkuYttCWBSIvc
    • Use a pair of tweezers to remove the battery connector bracket.

  15. QP1qNUfS2PQe1iJV
    QP1qNUfS2PQe1iJV
    VGqrYJhXrkXQWVXQ
    • Use the pointed end of a spudger to disconnect the battery cable by prying the connector straight up from its socket.

    • To re-attach press connectors like this one, carefully align and press down on one side until it clicks into place, then repeat on the other side. Don‘t press down on the middle. If the connector is misaligned, the pins can bend and cause permanent damage.

  16. pk4xKiDcTAnnU2rf
    pk4xKiDcTAnnU2rf
    WrDlvWBZEgHYwLtx
    fdDSEgxyLeCUVFFO
    • Remove the battery.

    • Don‘t reuse the battery if it has been deformed or damaged, as doing so is a potential safety hazard. Replace it with a new battery.

    • Secure a new battery with pre-cut adhesive or double-sided adhesive tape. In order to position it correctly, apply the new adhesive into the battery well at the places where the old adhesive was located, not directly onto the battery itself. Peel back any adhesive liners and press the new battery firmly into place.

    • If you're reusing your old battery, you can reuse the existing adhesive to secure the battery during reassembly.

  17. tLYe1rkCdDmVtxZ5
    tLYe1rkCdDmVtxZ5
    pUoyBGKjLlYtTVjC
    uoXHNy3DTrdo1PlU
    • Use a pair of tweezers to peel the black protective tape off both display connectors.

    • During reassembly, this is a good point to power on your watch and test all functions before sealing it up. Be sure to power your watch back down completely before you continue working.

  18. KHBbnHGu6SbucJXk
    KHBbnHGu6SbucJXk
    rWQOa1S2eHB2Y2hj
    ADK1MaFmKoM2UY26
    • Use the tip of a spudger to flip up the small, hinged locking flap on the display ZIF connectors.

  19. VMOhtLPlMhJdZ2Ph
    • Prepare an iOpener and apply it to the screen for two minutes to loosen the heat dissipation tape underneath.

    • A hair dryer, heat gun, or hot plate may also be used, but be careful not to overheat the watch—the display and internal battery are both susceptible to heat damage.

  20. vcX6XfBRosswrbrm
    vcX6XfBRosswrbrm
    EHeRhAPbE4V2Hw5o
    FisfPViW5DxOObaG
    • Slide an opening pick underneath the display cables to separate them from the screen.

  21. q6RRnQ5fTw2doj65
    q6RRnQ5fTw2doj65
    2PDZf5dKeROXT5LB
    • Use a pair of blunt nose tweezers to pull both display cables out of the ZIF connectors.

    • Avoid pulling on the watch assembly, or you may rip the display cables.

    • During reassembly, you can reuse your old heat dissipation tape if it's in good condition. Otherwise, replace it with new tape.

  22. XJkgTNawqvkKGMLE
    • Remove the screen.

Conclusion

If possible, turn on your device and test your repair before installing new adhesive and resealing.

To reassemble your device, follow these instructions in reverse order.

Take your e-waste to an R2 or e-Stewards certified recycler.

Repair didn’t go as planned? Check out our Answers community for troubleshooting help.

Dominik Schnabelrauch

Member since: 23/11/16

201162 Reputation

0 comments