IBM Storwize family

IBM Storwize systems are virtualizing RAID computer data storage systems with raw storage capacities up to 32 PB.[1] Storwize is based on the same software as IBM SAN Volume Controller (SVC).

Models

The Storwize family offers several members:[2]

  • IBM SAN Volume Controller – virtualizes multiple storage arrays
  • IBM FlashSystem 9100 - Capacity on up to 760 solid state modules and the capability to use up to 24 FlashCore modules
  • IBM Storwize V7000 Gen3 - Capacity on up to 760 modules (32 PB) and the capability to use FlashCore modules
  • IBM Storwize V7000 Gen2 - Capacity up to 4 PB and the capability to virtualize external storage
  • IBM Storwize V7000 – Capacity up to 1.92 PB and the capability to virtualize external storage
  • IBM Storwize V7000 Unified – provides file connectivity
  • IBM Storwize V5100 - Capacity on up to 760 modules and the capability to use FlashCore modules
  • IBM Storwize V5030E - capacity on up to 760 modules
  • IBM Storwize V5010E - capacity on up to 392 modules
  • IBM Storwize V5030 - capacity on up to 760 modules
  • IBM Storwize V5020 - capacity on up to 392 modules
  • IBM Storwize V5010 - capacity on up to 392 modules
  • IBM Storwize V5000 - capacity up to 960 TB
  • IBM Storwize V3700 – capacity up to 480 TB
  • IBM Storwize V3500 – capacity up to 48 TB (available in China, Hong Kong and Taiwan only)
  • IBM Flex System V7000 Storage Node – designed for integration with IBM PureSystems (Support withdrawn at SVC v7.3.0)

Each of the above family members run software that is based on a common source codebase, although each has a type specific downloadable package.

Architecture

Storwize V7000 provides a very similar architecture to SVC, using the RAID code from the DS8000 to provide internal managed disks and SSD code from the DS8000 for tiered storage.[3]

Features and software

All Storwize systems offer the following features:[4]

  • Command line interface
  • Graphical user interface (GUI) for easier use (CLI commands can be displayed as details), with (nearly) all functions available
  • Thin Provisioning known as Space Efficient Volumes
  • Volumes can be resized, i.e. expanded or reduced (only advisable, if supported by the operating system)
  • RAID levels 0,1,5,6,10
  • Distributed RAID (DRAID), i.e. DRAID-5 and DRAID-6
  • FlashCopy provides Snapshots with several combinations of these attributes: multiple, incremental, independent, space-efficient, immediately writable, or cascaded
  • Data Migration: data can be moved between all virtualized storage (both internal and external) with no disruption
  • Performance Management using throttling of bandwidth and transactions either by host or by volume
  • supports interactive and non-interactive ssh-login
  • supports several ways of call home and notifications (e-mail, syslog, SNMP, VPN-to-IBM, gui-based)
  • security functions, e.g. audit log, encrypted access

In addition, other Storwize systems offer the following features (some of them may require licenses):[5]

  • Automated tiered storage known as EasyTier, which supports hot spot removal within a tier (intra-tier) and between tiers (inter-tier)
  • Encryption for data at rest (all available original drives are self encrypting)
  • Peer to Peer Remote Copy
  • Metro Mirror (synchronous copy)
  • Global Mirror (asynchronous copy)
  • Global Mirror with Change Volumes (checkpointed asynchronous copy using flashcopies, e.g. for low bandwidth)
  • External Storage Virtualization
  • Virtual Disk Mirroring
  • Real-time Compression
  • Data Reduction Pools with Deduplication and Real-time Compression
  • Clustering, i.e. single user interface for several (up to 8) controllers, while supporting volume moves between them without disruption
  • Stretched cluster configuration (SVC only), optional "enhanced" version with site awareness (hardware redundancy only across sites)
  • Hyperswap (automated storage failover using the standard multipathing drivers; hardware redundancy on either site is given)

In addition, the Storwize V7000 Unified offered the following features:.[6]

  • File level storage (NAS)
  • Policy based file placement Active Cloud Engine
  • Global Namespace
  • Async replication on File level

Limitations

Most Storwize systems are intended for certain environments and provide several features, that are not licensed by default. There are several types of licenses that depend on the chosen model and the subject of the license:

  • licenses per net capacity (mainly with the SVC, where tiers can be treated differently)
  • licenses per enclosures (the controller and each expansion need one)
  • licenses per controller (just one license for all attached enclosures)

There are some limitations for each model and each licensed internal code. These can be read on IBMs web pages. Here are examples for V7000,[7] the V5000 series,[8] and IBM SAN Volume Controller.[9]

In addition, there are more contributors to a working environment. IBM provides this in an interactive interoperabitlity matrix called IBM System Storage Interoperation Center (SSIC).

Timeline

According to the official availability dates and the days the systems are removed from marketing you can determine the following availability to purchase shown in light green.

The graphics only contains the IBM storage systems starting with 'V', .i.e. V3700, V5000, V5010(E), V5020, V5030(E), V5100 and V7000. These systems vary even beyond their names, therefore the graphics also contains IBM type and model. All the displayed systems can still get regular service at the end of the timeline (beginning of 2020). After the light green purchase period, the time of regular service is displayed light blue. For the IBM SAN Volume Controller's timeline see there.

Hardware

The Storwize family hardware consists of control enclosures and expansion enclosures, connected with wide SAS cables (Four lanes of 6 Gbit/s or 12 Gbit/s). Each enclosure houses 2.5" or 3.5" drives. The control enclosure contains two independent control units (node canisters) based on SAN Volume Controller technology, which are clustered via an internal network. Each enclosure also includes two power supply units (PSUs).

Storwize V7000 Gen 3 (or 'Next Gen')

The IBM Storwize V7000 SFF Enclosure Model 724, announced November 6 2018, supports NVMe and FC-NVMe (NVMe/FC) on 16 Gbit/s or 32 Gbit/s adapters, and iSER (iSCSI Extensions for RDMA) or iSCSI on 25GbE adapters. The Control Enclosure holds twenty-four 2.5 inch NVMe flash drives or twenty-four 2.5 inch NVMe FlashCore modules. FlashCore modules contain IBM MicroLatency technology with built-in hardware compression and encryption.

  • Two node canisters, each with two 1.7 GHz eight-core Skylake (microarchitecture) processors and integrated hardware-assisted compression acceleration
  • 128 GiB cache (per I/O group) standard, with optional 256 GiB or 1.15 TiB cache per I/O group (node pair)
  • 32 Gbit/s fibre channel (FC) with NVMe support, 16 Gbit/s FC with NVMe support, 25 Gbit/s iSER and on board 10 Gbit/s iSCSI connectivity options
  • Clustering support over Ethernet using RDMA as well as Fibre Channel
  • Ability to cluster with older generations Storwize V7000 systems and with IBM FlashSystem 9100

Software Details:

  • First supported on the Storwize V7000 8.2.0.2 software.

Storwize V7000 Gen 2+

The IBM Storwize V7000 SFF Control Enclosure Model 624, announced 23 August 2016, features two node canisters and up to 256 GiB cache (system total) in a 2U, 19-inch rack mount enclosure. 1 Gbit/s iSCSI connectivity is standard, with options for 16 Gbit/s FC and 10 Gbit/s iSCSI/FCoE connectivity. It holds up to twenty-four 2.5-inch SAS drives and supports the attachment of up to 20 Storwize V7000 expansion enclosures.

IBM Storwize V7000 Gen 2+ is an updated Storwize V7000 Gen 2 with a newer CPU, doubled cache memory and faster FC options, integrated compression acceleration, and additional scalability with the following features:

  • Two node canisters, each with a ten-core Broadwell (microarchitecture) processor and integrated hardware-assisted compression acceleration
  • 128 GiB cache (per I/O group) standard, with optional 256 GB cache per I/O group (node pair) for Real-time Compression workloads
  • 16 Gbit/s Fibre Channel (FC), 10 Gbit/s iSCSI / Fibre Channel over Ethernet (FCoE), and 1 Gbit/s iSCSI connectivity options

Software Details:

  • First supported on the Storwize V7000 7.7.1 software.

Storwize V7000 Gen 2

The IBM Storwize V7000 SFF Control Enclosure Model 524, announced 6 May 2014, features two node canisters and up to 128 GiB cache (system total) in a 2U, 19-inch rack mount enclosure. 1 Gbit/s iSCSI connectivity is standard, with options for 8 Gbit/s FC and 10 Gbit/s iSCSI/FCoE connectivity. It holds up to twenty-four 2.5-inch SAS drives and supports the attachment of up to 20 Storwize V7000 expansion enclosures.

IBM Storwize V7000 next-generation models offer increased performance and connectivity, integrated compression acceleration, and additional scalability with the following features:

  • Two node canisters, each with an eight-core Haswell (microarchitecture) processor and integrated hardware-assisted compression acceleration
  • 64 GiB cache (per I/O group) standard, with optional 128 GB cache per I/O group (node pair) for Real-time Compression workloads
  • 8 Gbit/s Fibre Channel (FC), 10 Gb iSCSI / Fibre Channel over Ethernet (FCoE), and 1 Gb iSCSI connectivity options
  • 12 Gbit/s SAS expansion enclosures supporting twelve 3.5-inch large form factor (LFF) or twenty-four 2.5-inch small form factor (SFF) drives
  • Scaling for up to 504 drives per I/O group with the attachment of 20 Storwize V7000 expansion enclosures and up to 1,056 drives in a four-way clustered configuration
  • The ability to be added into existing clustered systems with previous generation Storwize V7000 systems
  • Compatibility with IBM Storwize V7000 Unified File Modules for unified storage capability
  • All models are delivered in a 2U, 19-inch rack mount enclosure and include a three-year warranty with customer replaceable unit (CRU) and on-site service. Optional warranty service upgrades are available for enhanced levels of warranty service.

Hardware Details:

  • The Storwize V7000 SFF Control Enclosure Model 2076-524 features:
    • Two node canisters, each with an eight-core processor and 32 GiB cache for a system total of 64 GiB cache
    • Four 1 Gbit/s Ethernet ports standard for 1 Gb iSCSI connectivity and IP management per node canister. One 1 Gbit/s Ethernet port is dedicated for Technician Access[10]
    • Up to two I/O adapter features for 8 Gbit/s FC and 10 Gbit/s iSCSI/FCoE connectivity
    • Supports up to twenty-four 2.5-inch drives
    • 2U, 19-inch rack mount enclosure
    • Storwize V7000 offers both LFF(2076-12F) and SFF(2076-24F) 12 Gb SAS expansion enclosure models.

Software Details:

  • First supported on the Storwize V7000 7.3.0 software.
  • The 7.4.0 software adds support for protection (SCSI T10 standard data integrity field (DIF)), encryption at rest and 4 KiB block drives.

Storwize V7000 family

Storwize V7000 consists of one to four control enclosures and up to 36 expansion enclosures, for a maximum of 40 enclosures altogether. It can scale up to 960 disks and 1.44PB raw internal capacity.[11]

Hardware details:

  • 2U rack-mountable chassis
  • Eight available enclosure models:
    • Type 2076-112 = Control enclosure – up to 12 3.5" drives
    • Type 2076-124 = Control enclosure – up to 24 2.5" drives
    • Type 2076-212 = Expansion enclosure – up to 12 3.5" drives
    • Type 2076-224 = Expansion enclosure – up to 24 2.5" drives
    • Type 2076-312 = Control enclosure – up to 12 3.5" drives + 10Gb iSCSI
    • Type 2076-324 = Control enclosure – up to 24 2.5" drives + 10Gb iSCSI
    • Type 2076-524 = Control enclosure – up to 24 2.5" drives + 10Gb iSCSI (known as V7000 Gen 2)
    • Type 2076-624 = Control enclosure – up to 24 2.5" drives + 10Gb iSCSI (known as V7000 Gen 2+)
    • Type 2076-724 = Control enclosure – up to 24 2.5" drives, NVMe flash drives or NVMe flash core modules + 10Gb iSCSI, 25 Gb iSER (known as V7000 Gen 3)
  • Up to 48 TB of physical storage per enclosure using 4 TB near-line SAS disk drives, or up to 28.8 TB physical storage per enclosure using 1.2 TB SAS 10K disk drives
  • Redundant dual-active intelligent controllers
  • 16 GB cache memory per control enclosure (8 GB per internal controller) as a base feature
  • For each control enclosure: Eight 8 Gbit/s Fibre Channel ports (four 8 Gbit/s FC ports per controller), four 1 Gbit/s iSCSI and optionally four 10 Gbit/s iSCSI/FCoE host ports (two 1 Gbit/s iSCSI and optionally two 10 Gbit/s iSCSI/FCoE ports per controller) or four 25 Gbit/s iSER host ports
  • Control enclosures support attachment of up to nine expansion enclosures with configurations up to 360 TB physical internal storage capacities (for Storwize V7000, up to 1.44 PB in clustered systems)
  • Dual power supplies and cooling components, the control enclosure PSUs each house a battery pack which retains cached data in the event of a power failure.
  • File module - V7000 Unified - provides attachment to 1 Gbit/s and 10 Gbit/s network-attached storage (NAS) environments

Storwize V5100

Storwize V5100 consists of a control enclosure and up to 20 standard expansion enclosures or 8 high-density expansion enclosures. It supports NVMe and FC-NVMe (NVMe-oF) on 16Gbit/s/32Gbit/s adapters, and iSCSI/iWARP/RoCE (iSCSI Extensions for RDMA) on 25GbE adapters. It can scale up to 760 disks and 23.34PB raw internal capacity.[12] Hardware details:

  • 2U rack-mountable chassis
  • Redundant dual-active intelligent controllers
  • 64 GB cache memory per control enclosure (32 GB per internal controller) as a base feature, expandable up to 1152GB per control enclosure
  • For each control enclosure: Eight 16 Gbit/s Fibre Channel ports (four 16 Gbit/s FC ports per controller), eight 32 Gbit/s FC-NVMe Fibre Channel ports, eight 10 Gbit/s iSCSI and optionally eight 25 Gbit/s iSCSI/iWARP/ROCE host ports
  • Dual power supplies and cooling components, the control enclosure PSUs each house a battery pack which retains cached data in the event of a power failure.

Storwize V5030E

Storwize V5030E consists of a control enclosure and up to 20 standard expansion enclosures or 8 high-density expansion enclosures. It can scale up to 760 disks and 23.34PB raw internal capacity.[13]

Storwize V5010E

Storwize V5010E consists of a control enclosure and up to 10 standard expansion enclosures or 4 high-density expansion enclosures. It can scale up to 392 disks and 12.04PB raw internal capacity.[14]

Storwize V5030

Storwize V5030 consists of a control enclosure and up to 20 standard expansion enclosures or 8 high-density expansion enclosures. It can scale up to 760 disks and 23.34PB raw internal capacity.[15]

Storwize V5020

Storwize V5020 consists of a control enclosure and up to 10 standard expansion enclosures or 4 high-density expansion enclosures. It can scale up to 392 disks and 12.04PB raw internal capacity.[16]

Storwize V5010

Storwize V5010 consists of a control enclosure and up to 10 standard expansion enclosures or 4 high-density expansion enclosures. It can scale up to 392 disks and 12.04PB raw internal capacity.[17]

Storwize V5000

Storwize V5000 consists of one to two control enclosures and up to 12 expansion enclosures, for a maximum of 18 enclosures altogether. It can scale up to 480 disks and 960TB raw internal capacity.[18]

Hardware details:

  • 2U rack-mountable chassis
  • Six available enclosure models:
    • Type 2078-12C = Control enclosure – up to 12 3.5" drives
    • Type 2078-24C = Control enclosure – up to 24 2.5" drives
    • Type 2078-212 = Expansion enclosure – up to 12 3.5" drives
    • Type 2078-224 = Expansion enclosure – up to 24 2.5" drives
    • Type 2078-12C = Control enclosure – up to 12 3.5" drives + 10Gb iSCSI
    • Type 2078-24C = Control enclosure – up to 24 2.5" drives + 10Gb iSCSI
  • Up to 48 TB of physical storage per enclosure using 4 TB near-line SAS disk drives, or up to 28.8 TB physical storage per enclosure using 1.2 TB SAS 10K SAS disk drives
  • Redundant dual-active intelligent controllers
  • 16 GB cache memory per control enclosure (8 GB per internal controller) as a base feature
  • For each control enclosure: Eight 8 Gbit/s Fibre Channel ports (four 8 Gbit/s FC ports per controller), four 1 Gbit/s iSCSI and optionally four 10 Gbit/s iSCSI/FCoE host ports (two 1 Gbit/s iSCSI and optionally two 10 Gbit/s iSCSI/FCoE ports per controller)
  • Control enclosures support attachment of up to six expansion enclosures
  • Dual power supplies and cooling components

SAN Volume Controller

An entry-level SAN Volume Controller configuration contains a single I/O group, can scale out to support four I/O groups and can scale up to support 4,096 host servers, up to 8,192 volumes and up to 32 PB of virtualized storage capacity.[19] For the full article, see IBM SAN Volume Controller.

Hardware details (per node - an I/O group consists of TWO nodes):

  • Based on IBM System x® 3650 M4 server
  • Processor: one (optionally, two) Intel Xeon E5-2650v2 2.6 GHz eight core processor
  • Optional compression accelerator cards (up to two)
  • 32 GB (optionally, 64 GB) of system memory
  • Four (optionally, eight or 12) 8 Gbit/s Fibre Channel ports
  • Three 1 Gbit/s and optionally four 10 Gbit/s iSCSI/FCoE ports
  • Supports up to two SSD expansion enclosures (up to 48 SSDs per I/O group)
  • Two power supplies and integrated battery units
  • 19-inch rack-mounted enclosure

Storwize V3700

Storwize V3700 consists of one control enclosure and up to 4 expansion enclosures. It can scale up to 240 2.5-inch disk drives or 120 3.5-inch disk drives and 480TB raw internal capacity.[20]

Hardware details:

  • 2U rack-mountable chassis
  • Four available enclosure models:
    • 2072-12C - Dual Control Enclosure – up to 12 3.5" drives
    • 2072-12E - Expansion Enclosure – up to 12 3.5" drives
    • 2072-24C - Dual Control Enclosure – up to 24 2.5" drives
    • 2072-24E - Expansion Enclosure up to 24 2.5" drives
  • Control enclosure networking: 4 x 1 Gb iSCSI and 6 x 6 Gbit/s SAS host interfaces with optional 8 Gbit/s Fibre Channel, further 6Gbit/s SAS or 10 Gb iSCSI/Fibre Channel over Ethernet host ports
  • Dual-port, hot-swappable 6 Gb SAS disk drives
  • 8 GB cache memory per control enclosure (4 GB per internal controller) as a base feature, upgradeable to 16 GB cache (8 GB per internal controller)
  • Redundant, hot-swappable power supplies and fans
  • AC power (110 – 240 V)

Flex System V7000 Storage Node

Flex System V7000 can scale up to 240 (2.5" disks) per control enclosure; 960 (2.5" disks) per clustered system. This is not supported at v7.3.0.

Hardware details:

  • Redundant dual-active intelligent controllers
  • 16 GB cache memory per control enclosure (8 GB per internal controller) as a base feature
  • SAN-attached 8 Gbit/s Fibre Channel, 10 Gigabit Ethernet (GbE) FCoE and iSCSI host connectivity
  • Control enclosures support attachment of up to nine expansion enclosures (internal and external mix) with configurations up to 960 drives.
gollark: Yes, they are. Unfortunately, I was temporarily using Lua, which uses 1-based indexing.
gollark: SCP-SCP-033
gollark: Go [DATA EXPUNGED] yourself.
gollark: ···
gollark: If you really want you can do ██████ redactions.

References

  1. "IBM Storwize family". IBM. Retrieved 6 May 2013.
  2. "We are family ! – Meet the IBM Storwize Family". Storage CH Blog. Retrieved 6 May 2013.
  3. "IBM's New Midrange with Easy Tier & External Virtualization". The Storage Buddhist. Retrieved 6 May 2013.
  4. "Storwize V3700 overview". IBM Storwize V3700 Version 6.4.1. IBM. Retrieved 6 May 2013.
  5. "Storwize V7000 overview". IBM Storwize V7000 Version 6.4.1. IBM. Retrieved 6 May 2013.
  6. "Storwize V7000 Unified overview". IBM Storwize V7000 Unified Version 1.4. Retrieved 6 May 2013.
  7. "Support Information for Storwize V7000". IBM Storwize V7000 from V6.1 to V8.3. Retrieved 28 August 2019.
  8. "Support Information for SAN Volumes Controller". IBM SAN Volumes Controller from V4.3 to V8.3. Retrieved 28 August 2019.
  9. "Support Information for Storwize V5000". IBM Storwize V5000, V5000E, V5030F and V5100 from V7.1 to V8.3. Retrieved 28 August 2019.
  10. https://www.ibm.com/support/knowledgecenter/ST3FR7_7.4.0/com.ibm.storwize.v7000.740.doc/svc_portsandconnect_gen2.html
  11. "IBM Storwize V7000 and Storwize V7000 Unified Disk Systems". IBM. Retrieved 6 May 2013.
  12. "IBM Storwize V5030E". IBM. Retrieved 14 Aug 2019.
  13. "IBM Storwize V5030E". IBM. Retrieved 14 Aug 2019.
  14. "IBM Storwize V5010E". IBM. Retrieved 14 Aug 2019.
  15. "IBM Storwize V5030". IBM. Retrieved 14 Aug 2019.
  16. "IBM Storwize V5020". IBM. Retrieved 14 Aug 2019.
  17. "IBM Storwize V5010". IBM. Retrieved 14 Aug 2019.
  18. "IBM Storwize V5000". IBM. Retrieved 16 Aug 2014.
  19. "IBM System Storage SAN Volume Controller". IBM. Retrieved 16 Aug 2014.
  20. "IBM Storwize V3700". IBM. Retrieved 16 Aug 2014.
This article is issued from Wikipedia. The text is licensed under Creative Commons - Attribution - Sharealike. Additional terms may apply for the media files.