Einthoven's triangle

Einthoven's triangle is an imaginary formation of three limb leads in a triangle used in electrocardiography, formed by the two shoulders and the pubis.[1] The shape forms an inverted equilateral triangle with the heart at the center. It is named after Willem Einthoven, who theorized its existence.[2]

Graphical representation of Einthoven's triangle

Einthoven used these measuring points, by immersing the hands and foot in pails of salt water, as the contacts for his string galvanometer, the first practical ECG machine.[3]

Lead placements

  • Lead I — This axis goes from shoulder to shoulder, with the negative electrode placed on the right shoulder and the positive electrode placed on the left shoulder. This results in a 0 degree angle of orientation.[4]
  • Lead II — This axis goes from the right arm to the left leg, with the negative electrode on the shoulder and the positive one on the leg. This results in a +60 degree angle of orientation.[4]
  • Lead III — This axis goes from the left shoulder (negative electrode) to the right or left leg (positive electrode). This results in a +120 degree angle of orientation.[4]

Electrodes may be placed distally or proximally on the limb without affecting the recording.[5] The right leg electrode acts to reduce interference, and can be placed anywhere without an effect on the ECG results.[6]

Each lead measures the electric field created by the heart during the depolarization and repolarization of myocytes. The electric field can be represented as a vector that changes continuously and can be measured by recording the voltage difference between electrodes.[7]

Using Einthoven's triangle to identify lead misplacements

Though Einthoven's triangle is no longer used in contemporary ECGs, Einthoven's triangle can be helpful in the identification in incorrect placement of leads. (Incorrect placement of leads can lead to error in the recording, which can ultimately lead to misdiagnosis.)

If the arm electrodes are reversed, lead I changes polarity, causing lead II and lead III to switch. If the right arm electrode is reversed with the leg's electrode, lead II changes polarity, causing lead I to become lead III, and vice versa. Reversal of the left arm and leg causes a change in polarity of lead III and switching of leads I and II.[6]

gollark: Maybe you could use QUIC, also.
gollark: SCTP (and HTTP/2 actually) support independent data streams.
gollark: They probably just send VAST volumes of data over the stream and wait for it to arrive.
gollark: It may be slightly nonexistent for Windows users, but that's their fault.
gollark: > Reliable transmission of both ordered and unordered data streams.> Explicit partial reliability.

References

  1. Lippincott Williams & Wilkins (1 August 2009). ECG Facts Made Incredibly Quick!. Lippincott Williams & Wilkins. p. 5. ISBN 978-1-60547-476-2.
  2. Understanding Electrocardiography. Elsevier Health Sciences. 2003. p. 4. ISBN 0-323-01905-6.
  3. Silverman, M. E. (1992-10-01). "Willem Einthoven--the father of electrocardiography". Clinical Cardiology. 15 (10): 785–787. doi:10.1002/clc.4960151020. ISSN 0160-9289. PMID 1395193.
  4. The Only EKG Book You'll Ever Need. Lippincott Williams & Wilkins. 2003. p. 40. ISBN 0-7817-4176-9.
  5. Klabunde, Richard E (2005-01-01). Cardiovascular Physiology Concepts. Lippincott Williams & Wilkins. pp. 34–35. ISBN 9780781750301.
  6. Abi-Saleh, Bernard; Omar, Bassam (2010-01-01). "Einthoven's triangle transparency: a practical method to explain limb lead configuration following single lead misplacements". Reviews in Cardiovascular Medicine. 11 (1): 33–38. ISSN 1530-6550. PMID 20495514.
  7. Richardson, Daniel R.; Randall, David Clark; Speck, Dexter F. (1998-03-13). Cardiopulmonary System Structure and Function. Hayes Barton Press. pp. 99–101. ISBN 9781889325309.


This article is issued from Wikipedia. The text is licensed under Creative Commons - Attribution - Sharealike. Additional terms may apply for the media files.