Introduction

Follow this guide to remove the primary plastic housing cover on the Karcher Rotary Floor Cleaner 17833080 2017 for further disassembly.

  1. cvdMERNHLdUGDK3b
    cvdMERNHLdUGDK3b
    StNjh5BI2IvnEQgF
    • Before you begin, make sure to power off and unplug the device.

    • Lift the tank by the handle and remove it from the device.

  2. jBy4DhMReckHQHZh
    jBy4DhMReckHQHZh
    Hnij1DGCDlHW4sWX
    2LQL2UnDUNjrlHnq
    • Press the yellow button near each wheel base to release the wheels.

    • Remove both wheels from their sockets.

  3. FA3CopeIFuaRydth
    FA3CopeIFuaRydth
    GxBBReuQTfSYLUCo
    • Press the yellow foot switch at the base of the device to lower the suction bars.

  4. HJFVENmeE2ED3qLd
    HJFVENmeE2ED3qLd
    uN1XHJpZGwge6N4w
    • Raise the handle to the upright position.

    • This will engage the carriage rollers and lift the device.

  5. lKv1SQdCFVICW3hv
    lKv1SQdCFVICW3hv
    ayVpTWW6bU4duAg3
    • Engage the retaining bracket to lock the handle in place.

  6. qYBSGrE6XE2GS1x6
    qYBSGrE6XE2GS1x6
    1aUG4gMlHmemSyjl
    BNqNhOyV4dSGA6Qe
    • Grasp the handle and carefully tilt the device onto its side.

  7. KQhHclU2fjTidAGI
    KQhHclU2fjTidAGI
    dtQTpIuVSk34uTwN
    jorGlN6QO5MWwQsJ
    • Tilt the top of the roller brush out of the brush well.

    • Remove both roller brushes.

  8. veGs2dJwBwa6eawq
    veGs2dJwBwa6eawq
    KjRFymTSLQbLFdtl
    TSJHEMK1FGHKtobk
    • Press the yellow button on the suction bar retaining bracket to release the suction bar.

    • If you can't see the yellow button, press the yellow foot switch at the base of the device to lower the suction bars.

  9. uLWahWmRMgEO1fMv
    uLWahWmRMgEO1fMv
    3hGreQXbreCU6Cvc
    • Remove both suction bars.

    • Reassembly tip: When you re-insert the suction bars, be sure to orient the locking tab towards the center of the device. This allows the bars to click in place.

  10. IYb1ZxJGGNdsuakj
    • Use a T20 driver to remove the three screws securing the pump cover.

  11. NZ5EyFkomPZKLavV
    NZ5EyFkomPZKLavV
    OdPYSm3UEYqN5aHp
    fivHaIJQuYuAlWa5
    • Remove the pump cover.

  12. FEioVCLT2VDWHkBK
    FEioVCLT2VDWHkBK
    uvUye2YRAQBi3gBI
    • Squeeze the right plug by the edges and pull it out of its socket.

    • During reassembly, make sure that all plugs are firmly seated in their sockets.

  13. mVyA1tRUKYy4E5XU
    • Remove the following screws securing the left retaining bracket:

    • Four T40 screws

    • Two T20 screws

  14. mSCZdgbKDs6ixCvl
    mSCZdgbKDs6ixCvl
    FM1TCL2ZcwH4obKl
    L4hPFHgLcGWl2y2W
    • Raise the handle to the upright position.

    • This will engage the carriage rollers and lift the device.

    • Engage the retaining bracket to lock the handle in place.

  15. TDKFfTYHSig4M6ro
    • Use a T20 driver to remove the two screws securing the right splash guard.

  16. fD1lJDWaHQvlWqpn
    fD1lJDWaHQvlWqpn
    VMBUtxyp1gI6gGup
    • Remove the right splash guard.

  17. ONkjTLw4Ee2kJYij
    • Use a T20 driver to remove the following screws securing the right retaining bracket:

    • Two 85 mm-long screws

    • Four 45 mm-long screws

  18. PUPlOCjAdwoyl223
    PUPlOCjAdwoyl223
    PWMYINggCCObSMSK
    • Remove the right retaining bracket.

  19. sUHqq1lGjnKF1ReT
    sUHqq1lGjnKF1ReT
    SOT4fPLV1DQyOJhp
    4XqClGBNMMuDiGdA
    • Lift the handle assembly away from the device and remove it.

  20. BVhV1ZmeYFX12hMt
    • Reassembly tip: Be careful not to lose the two gray bushings on the ends of the handle assembly.

  21. HbWidO1n63djCXDU
    HbWidO1n63djCXDU
    GinUuBoRbp5RBfZG
    • Disconnect the two remaining plugs by squeezing the edges and pulling them out of their sockets.

    • The socket board should have no plugs connected to it.

    • Reassembly tip: The sockets reconnect to the following parts:

    • Vacuum motor

    • Pump

    • Handle

    • During reassembly, make sure to firmly seat all plugs in their sockets.

  22. nnYNBuoAsBLaxFOg
    • Use a T20 driver to remove the six screws securing the plastic brush housing.

  23. Kn1BPrtpKxGEo5Rh
    Kn1BPrtpKxGEo5Rh
    2VSoxVRLM4wRLRTl
    1LrwFccTR1PYvMvZ
    • Lift the brush housing away from the device and remove it.

Conclusion

To reassemble your device, follow these instructions in reverse order.