Introduction

This guide will show you how to replace a motor tread.

  1. ZKKD2ODgdNE6ycPL
    ZKKD2ODgdNE6ycPL
    b3GsvWC5ZEMIYNKA
    kbNJVPUgVaKWgf3t
    • Loosen the screws on the serial port by turning them counter clockwise by hand.

    • After loosening the screws, pull the serial port out.

  2. dkFDbiKh1FEcQKJK
    dkFDbiKh1FEcQKJK
    n3WnQouIh6cnqyS2
    EnTuXlHFPdBOoHty
    • Lift lid to its vertical position.

    • Pull lid straight up to remove it from the scanner.

  3. wLDWDV2XaeuNmpR5
    wLDWDV2XaeuNmpR5
    jZnPhPqcLxoDQkg5
    HXGHaRfAp22jpQku
    • Push the plastic opening tools into the crack between the top and the bottom of the chassis.

  4. nSCVSiNHmwuLSBUr
    nSCVSiNHmwuLSBUr
    cXOp6JdrHXFk6vmy
    DKBPirTImIWRYKAS
    • After placing one plastic opening tool into the slit, slide other plastic opening tools along the slit to detach the top from the bottom of the chassis.

    • Go all the way along the chassis until you can lift the upper lid.

  5. 5qZS4ybAA1THHcEQ
    5qZS4ybAA1THHcEQ
    w2IceuWIHWxxNUHs
    nYJWZ5uCTvfc1UsO
    • Do not fully remove the lid until you remove the ribbon cable attached to the front of the upper lid.

    • Do this by grabbing the upper lid from the sides and rotating it ninety degrees so it is perpendicular to the bottom lid.

    • Grab the ribbon cable and gently pull it out of its slot with your fingers.

    • The upper lid can now safely be removed from the bottom lid.

  6. SWhpruBcxAqRtWnn
    SWhpruBcxAqRtWnn
    GKChKGdURewDCK26
    • Locate the stepper motor. With the front of the scanner facing you, the motor is located at the top left.

    • Disconnect the white connector from the vertical standing circuit board.

  7. 2SRlStbgxuRRdxSR
    2SRlStbgxuRRdxSR
    DwrKSRtJldGynxAT
    WNPUR3I4SwygTWW2
    • Using a #2 Philips Screwdriver, unscrew the two 7.7mm screws holding the stepper motor in place.

    • The stepper motor will become loose, but not completely free.

  8. T23hRbHLK2GuIdw1
    T23hRbHLK2GuIdw1
    SbPLckNa5FVBnEXq
    VaRt1MyuInNHAPhO
    • Using tweezers gently remove the tread from the black gear on the stepper motor.

    • The stepper motor will become completely free.

  9. FplMb5HahDXmI1KD
    FplMb5HahDXmI1KD
    YaB2qll5FXiTt4lv
    • Facing the front of the scanner you will see a white plastic wheel holding the other end of the tread.

    • Pull the spring towards you until it snaps off the side wall releasing the tension in the spring.

    • Using a #2 Philips Screwdriver, unscrew the single 5.88mm screw holding the mount of the plastic wheel in place.

  10. sdFvXVFkNTZf26Kk
    • The plastic wheel and it's mount will be loose.

    • Remove the shaft holding the plastic wheel and the mount together

    • The tread will be completely loose.

Conclusion

To reassemble your device, follow these instructions in reverse order.