Introduction

This guide will give you step-by-step instructions on how to replace the record slider on your Contour Roam2 waterproof action camera if the camera won't begin or end recording properly.

  1. 2eyQI53cPEaC34cK
    • Using the phillips head screwdriver (PH000) locate and remove the 4.45mm (.175in) screw by the 180 degree graphic on the metal ring.

    • The screws in the camera are very small and can strip very easily. Apply consistent pressure when removing screws.

  2. oTLH2WrKrS2Srrjm
    oTLH2WrKrS2Srrjm
    lMVeWroDUHesHkUh
    • Rotate the metal ring counterclockwise until completely removed.

  3. IH4bqygpVk3NwZ2g
    IH4bqygpVk3NwZ2g
    ptu2mObGmTnxvSjQ
    • Using the phillips head screwdriver (PH000) remove the two 4.46mm (.175in) screws on each side near the back of the camera.

  4. uiOiSJoDHfiwcl3Q
    uiOiSJoDHfiwcl3Q
    Lmo5YuwAdxMTLwcC
    NfgNMAsratxYsNRB
    • Grab the camera on both sides and slide the outer shell forward until completely removed.

  5. tKriiUjtLEKWje3v
    • Lift the record slider out.

    • The record slider should come out easily no matter the position (forward or backward).

Conclusion

To reassemble your device, follow these instructions in reverse order.

Matthew Kofsky

Member since: 11/03/15

548 Reputation

2 comments

I have had this camera since I was 16 I am 21 now and there was something wrong with the slider I am glad I didn't get rid of it! Because of you it is fixed now!!!

Neiko Rivera (Specters) -

Dose anyone know if there is an equivalent guide but for the “Contour +2”?

Christopher Hinrichs -