Introduction

This guide demonstrates how to quickly and safely replace the run capacitor in your residential condenser unit. The average life span of an AC capacitor is about 8-10 years. A way to check if the capacitor is dead is to look for a visual cue. Usually, it will have a bulging appearance on the top of the cylinder, similar to a can bursting open at the top.

Check the ratings on your old capacitor in the condenser unit so you can buy the correct replacement capacitor. The condenser unit that appears in this guide is a Goodman model. The model number for the condenser unit is GSX130481BC. The capacitor for this unit was rated at 45/5 uf and 370 or 440 Volts.

This guide is only for replacing the AC capacitor in a condenser unit. If you believe that there is a different issue with the condenser unit, look for the condenser model number and research troubleshooting guides. Another option is to hire a HVAC technician.

When following this guide, please always remember safety first. Remember to turn the power off before you start and turn it back on only after you have everything reassembled.

  1. Y3HlEfNLXuCR2FSZ
    Y3HlEfNLXuCR2FSZ
    vwpAv2u36XjIKdTK
    • Go to the condenser unit outside the house and locate the breaker panel connected to the unit.

  2. WGrvdGCYbVoYFAsK
    WGrvdGCYbVoYFAsK
    UumVyv2Yln3rZXEj
    3QusEQdhq1VDwDlG
    • Open the breaker panel and pull out the fuse inside.

    • Turn off the power by removing the fuse or flipping the switch on the disconnect box before continuing on with the guide. Leaving the power on during repair could result in serious injury or death.

  3. Jp6GLXQZgmBaSaUv
    Jp6GLXQZgmBaSaUv
    KBULOIyOhmwcRaTS
    ibJtpKeWZtwF2dBH
    • Locate the Electrical panel hiding the capacitor and unscrew the panel from the condenser unit using the screwdriver or the drill bit

    • Usually, there are two screws on the bottom of the electrical panel that are the screws holding the panel to the condenser unit.

    • Screw size/type is dependent on the model of the condenser unit.

  4. w2m6SPZTEfQCpwW6
    w2m6SPZTEfQCpwW6
    gijnmCsVMvOGdGTu
    Ifn1iFR53EewXLXk
    • Some condenser units have 1 run capacitor, some have 2. Steps are the same for each but you have to buy replacements for each capacitor.

    • Do not touch the metal part of the wires. They are still connected to a charged capacitor and can still shock you. Pull wires from the insulated parts.

    • Take pictures or remember where each colored wire is connected, and pull each wire straight up to disconnect from capacitor.

  5. iFJketJPXNUxMkEo
    iFJketJPXNUxMkEo
    NeKLXc2HrhAmZKC1
    MpcTJiWGYxUgeHKE
    • Locate the bracket holding the capacitor to the condenser unit and unscrew it.

    • Screw size/type is dependent on the model of the condenser unit.

  6. eoajmcXPsy4lO1kx
    eoajmcXPsy4lO1kx
    q1FNMVg1oTFhRRXJ
    Gi1DSSXdAxXRiD2i
    • Using the capacitor discharge pen, connect wire lead to the common terminal of the capacitor, the 'C' side of the capacitor. Then touch the brass tip of the capactior to any nearby ground, frame, or chassis.

    • Repeat these steps with the herm side and then the fan side of the capacitor to a nearby ground, frame, or chassis.

    • After discharging the capacitor, you can safely dispose of the capacitor responsibly.

    • Harzardous situation which can result in injury or death. The discharge process should only be used with a certified capacitor discharge tool.

    • Most state or local government websites will have information on how to dispose of electronics safetly.

  7. oDs5SdelxZ2hRAxR
    oDs5SdelxZ2hRAxR
    y3ZeFd5uioQHNTry
    FTOsEMZq4YV6Y65K
    • With the new capacitor, plug in the color wires to each terminal the wires were connected to on the old capacitor.

    • Reference images about the capacitor wiring are very helpful in this step.

  8. 3KCPKAI2jVikIBUO
    3KCPKAI2jVikIBUO
    HYRBNHSlqkMfaMU3
    • Put the capacitor against the unit, align the bracket to the screw socket, and screw it the bracket.

  9. EiuxMTGtX6ImmvA3
    EiuxMTGtX6ImmvA3
    2rcBWxMd1vrs5bTi
    TyjRFDw2FmmlhAI4
    • Put the electrical panel back into place, and screw it back onto the condenser unit.

  10. W4jpn1WH1HrUaCUa
    W4jpn1WH1HrUaCUa
    ajUGMYMHgZB1vvfK
    lQUMGekA6WMAwYUY
    • Put the fuse back into the breaker panel.

    • Remember to have completed all the previous steps before putting the fuse back in the breaker panel.

    • The circuit should be on once the fuse is plugged back into the panel.

Conclusion

Follow these instructions and replacing the capacitor will be easy.